homepage  Research  Publications  2012
 
K. B. An, Y. P. He, Z. H. Li, W. Z. Mi and J. Wang (2012) Journal Of Fire Sciences 30 552-565.
Date: 2013-08-22   Author: SKLFS  ,   Source: WOS  ,
 

K. B. An, Y. P. He, Z. H. Li, W. Z. Mi and J. Wang (2012) A study of ignition of timber by incandescent lamp. Journal/Journal Of Fire Sciences 30 552-565. [In English]
Web link: http://dx.doi.org/10.1177/0734904112450840
Keywords: Minimum heat flux, nonpiloted ignition, wood, fire investigation, time, of ignition, critical ignition distance
Abstract: In this article, a study is reported on the ignition of timber board by an incandescent light. A set of experimental tests were conducted to demonstrate the possibility of such an event. Inference was then made to the possible cause of a fire incident that occurred at a building construction site a few years ago. Theoretical analysis was also conducted based on an ignition model. The model is able to correlate the time to ignition with the distance between the light bulb with a given power output and the timber board.

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176