P. Zhu, X. S. Wang, Y. P. He, C. F. Tao and X. M. Ni (2016) Flame characteristics and burning rate of small pool fires under downslope and upslope oblique winds. Journal/Fuel 184 725-734. [In English]
Web link: http://dx.doi.org/10.1016/j.fuel.2016.07.059
Keywords: ,Combustion characteristic, Pool fire, Flame tilt angle, Flame length, Oblique wind, AIR-FLOW, TUNNEL, FIELD

Abstract: This paper presents an experimental investigation on burning rate, flame tilt angle and flame length of small ethanol pool fires under different oblique winds. Square pool fires with dimension of 4 cm and 6 cm with wind attack angles from 0 degrees to 30 degrees and wind speeds from 0 to 3.28 m s (1) for downslope airflow and from 0 to 1.90 m s (1) for upslope airflow are tested. Flame tilt angle and flame length are determined based on luminous flame intermittency from the flame images. The results show that the burning rate under downslope wind is relatively larger than that under upslope wind at the same absolute wind speed and slope angle. The flame tilt angle and flame length generally increase with the increase of wind slope angle for downslope airflow, but decrease with the increase of upslope airflow angle. At a given wind slope angle, the flame tilt angle generally increases with the increase of wind speed until to an asymptotic value when the wind speed exceeds 0.35 m s (1), the flame length first increases and then decreases for downslope wind, but initially decreases then increases before decrease again for upslope wind. In addition, some modified correlations are developed to analyze the flame tilt angle and flame length data under oblique wind conditions. (C)2016 Elsevier Ltd. All rights reserved.

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176