homepage  Research  Publications  2016
 
Z. H. Gao, Z. X. Liu, J. Ji, C. G. Fan, L. J. Li and J. H. Sun (2016) Applied Thermal Engineering 102 1314-1319.
Date: 2017-03-14   Author: SKLFS  ,   Source: SKLFS  ,
 

Z. H. Gao, Z. X. Liu, J. Ji, C. G. Fan, L. J. Li and J. H. Sun (2016) Experimental study of tunnel sidewall effect on flame characteristics and air entrainment factor of methanol pool fires. Journal/Applied Thermal Engineering 102 1314-1319. [In English]
Web link: http://dx.doi.org/10.1016/j.applthermaleng.2016.03.025
Keywords: ,Flame height, Air entrainment factor, Methanol pool fire, Sidewall, effect, TURBULENT-DIFFUSION FLAMES, PLUMES, CORNER, WALL

Abstract: This paper presents an experimental investigation to explore the effect of tunnel sidewall on flame characteristics and air entrainment factor of niethanol pool fires with decreasing distance to the sidewall. Experimental results show that owing to the confinement effect of sidewall, the flame height increases with the decrease of fire-sidewall distance. Especially for fire immediately against sidewall, the air entrainment process is confined to the largest extent and the flame height increases significantly. Correlations of the flame height with difference distances to the sidewall are obtained based on the dimensionless analysis and experimental data. Besides, the Entrainment Factor (EF), which describes the ratio of air entrainment into the confined plume relative to the unconfined one, is estimated for different fire locations. When fire is flush with sidewall, the Entrainment Factor (EF) decreases to 0.46, meaning that only 0.46 times of air is entrained into the flame volume compared to the fire at the longitudinal centerline of tunnel. The flame height and Entrainment Factor under the experimental conditions are also compared to the previous results. (C) 2016 Elsevier Ltd. All rights reserved.

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176