homepage  Research  Publications  2016
 
G. Z. Shao, Q. S. Wang, H. Zhao, Y. Wang, J. H. Sun, L. H. He, Q. S. Wang and J. H. Sun (2016) Fire Technology 52 563-580.
Date: 2017-03-09   Author: SKLFS  ,   Source: SKLFS  ,
 

G. Z. Shao, Q. S. Wang, H. Zhao, Y. Wang, J. H. Sun, L. H. He, Q. S. Wang and J. H. Sun (2016) Thermal Breakage of Tempered Glass Fa double dagger ade with Down-Flowing Water Film Under Different Heating Rates. Journal/Fire Technology 52 563-580. [In English]
Web link: http://dx.doi.org/10.1007/s10694-015-0499-5
Keywords: ,Tempered glass, Thermal breakage, Water film, Heating rate, Fire, WINDOW GLASS, RADIANT EXPOSURE, FIRE, PANE, TRANSMISSION, RESISTANCE, SPRINKLER, SINGLE, FIELDS

Abstract: The objective of this work is to investigate the effect of the heating rate on the thermal breakage and fallout behavior of the tempered glass with down-flowing water film. The heating rate of the glass panes was controlled by changing the distance between the fire source and the glazing surface, which ranged from 0.6A degrees C s(-1) to 1.0A degrees C s(-1). N-heptane pool fire was adopted to heat up the glass panes and the fuel pan was positioned 500 or 600 mm away from the exposed glass surface. During the experiments the water film was initiated manually when the maximum glazing temperature reached different designed values. The results show that all the glazing panes kept their integrity when the fire source distance was 500 mm. In contrast, all the glass panes cracked and fell out the frame when the fire source distance was 600 mm except the one with the water film discharged at 200A degrees C. The results illustrate that the heating rate plays a key role on the breakage of glass fa double dagger ades. Under the effect of water film or sprinkler system, glass panes are more likely to fail when exposed to a fire with smaller heat release rate or greater distance, rather than the opposite case.

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176