J. Lei, N. A. Liu, L. H. Zhang and K. Satoh (2015) Combustion And Flame 162 745-758.
Date: 2016-02-29   Author: SKLFS  ,   Source: SKLFS  ,
 

J. Lei, N. A. Liu, L. H. Zhang and K. Satoh (2015) Temperature, velocity and air entrainment of fire whirl plume: A comprehensive experimental investigation. Journal/Combustion And Flame 162 745-758. [In English]
Web link: http://dx.doi.org/10.1016/j.combustflame.2014.08.017
Keywords: Fire whirl plume, Temperature, Axial velocity, Tangential velocity, Mass, flow rate, Entrainment coefficient, COMBUSTION DYNAMICS, STRATIFIED FLOWS, TURBULENT, PREDICTION, FLAMES
Abstract: Comprehensive measurements were performed to examine the temperature, velocity (in axial and tangential directions) and air entrainment of propane fire whirl plume in a medium-scale fixed-frame facility. It is found that the radial profile of excess temperature varies consistently with the continuous flame shape and the radial decay rate of excess temperature decreases in the intermittent flame and plume. The centerline axial velocity depends on both the buoyancy and the axial pressure gradient related to the tangential velocity. A weak annular reverse flow is found outside the upward core at z/D <,= 1.0, while the absolute axial velocity slightly increases with fire size. The growth of axial velocity core is found to be constrained by the reverse flow. The mean axial velocity radius is confirmed to be greater than the mean excess temperature radius in the continuous flame. The radial profile of tangential velocity varies steadily with height, and is little affected by heat release rate. The radial swirl flow consists of the vortex core, the quasi-free vortex and the near wall region, and the active reaction occurs in the vortex core. The plume growth rate increases with decreasing Ri(B) (Richardson number) and three distinct regions are identified in different RiB ranges. The air entrainment is strong at the bottom inflow boundary layer, while the mass flow rate increases slowly with height as compared to buoyant pool fires. The suppression of air entrainment may be attributable to the radial force balance and stable stratification in the centrifugal acceleration filed. The entrainment coefficient in the continuous flame is about one to two orders of magnitude lower than that in a buoyant pool fire, and it generally increases with height in the plume of fire whirl, approaching the value for pure buoyant plume. The mean entrainment coefficient depends on the mean RiB by -1 power law for z <,= H-f. (C) 2014 The Combustion Institute. Published by Elsevier Inc. All rights reserved.


 ,

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176