P. Y. Wen, X. F. Wang, B. B. Wang, B. H. Yuan, K. Q. Zhou, L. Song, Y. A. Hu and R. K. K. Yuen (2014) Polymer Degradation And Stability 110 165-174.
Date: 2015-03-25   Author: SKLFS  ,   Source: SKLFS  ,
 

P. Y. Wen, X. F. Wang, B. B. Wang, B. H. Yuan, K. Q. Zhou, L. Song, Y. A. Hu and R. K. K. Yuen (2014) One-pot synthesis of a novel s-triazine-based hyperbranched charring foaming agent and its enhancement on flame retardancy and water resistance of polypropylene. Journal/Polymer Degradation And Stability 110 165-174. [In English]
Web link: http://dx.doi.org/10.1016/j.polymdegradstab.2014.08.019
Keywords:��olypropylene, Hyperbranched charring foaming agent, Flame retardance, Thermal stability, Water resistance, AMMONIUM POLYPHOSPHATE, THERMAL-DEGRADATION, POLYMERS, PHOSPHORUS, PENTAERYTHRITOL, POLYURETHANE, PERFORMANCE, RESIN

Abstract: A novel hyperbranched charring foaming agent (HCFA), successfully prepared via an A(2)B(3) approach with about 97% yield, was combined with ammonium polyphosphate (APP) to flame-retard polypropylene (PP) at a 30 wt% loading. The results of thermogravimetric analyses of various PP samples in air and nitrogen showed that the HCFA/APP system could effectively improve the thermal and thermal-oxidative stabilities of the char residues. And PP3 with a 3/1 mass ratio of APP to HCFA left the highest amount of char residue at 800 C. The studies of their flammability revealed that the addition of HCFA can make great contribution to the increase of the limiting oxygen index and the UL-94 VU rating, and the decrease of the heat release rate (HRR) and fire growth index (FGI) of PP/APP/HCFA composites relative to PP with 30 wt% APP. The investigation of their water resistance demonstrated that the PP composites with a mass ratio of APP to HCFA being between 3:1 and 1:1 still obtained a UL-94 V-0 rating after 168 h soaking in hot water, due to the delayed migration of intumescent flame retardant from the complexation between hydrophilic APP and hydrophobic HCFA. Besides, their mechanical properties were also investigated. (C) 2014 Published by Elsevier Ltd.

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176