Zhu N, Jiang Y, Kato S (2005) Ultrasonic computerized tomography (CT) for temperature measurements with limited projection data based on extrapolated filtered back projection (FBP) method. Energy 30(2-4), 509-522. [In English]
Web link:http://dx.doi.org/10.1016/j.energy.2004.09.005
Keywords:
reconstruction,
Abstract: This study uses ultrasound in combination with tomography to obtain three-dimensional temperature measurements using projection data obtained from limited projection angle. The main feature of the new computerized tomography (CT) reconstruction algorithm is to employ extrapolation scheme to make tip for the incomplete projection data, it is based on the conventional filtered back projection (FBP) method while on top of that taking into account the correlation between the projection data and Fourier transform-based extrapolation. Computer simulation is conducted to verify the above algorithm. An experimental mental 3D temperature distribution measurement is also carried out to validate the proposed algorithim. The simulation and experimental results demonstrate that the extrapolated FBP CT algorithm is highly effective in dealing with projection data from limited projection angle. (C) 2004 Elsevier Ltd. All rights reserved.