homepage  Research  Publications  2009
 
Zhang QX, Wang JJ, Liu BH, Cai TL, Qiao LF, Zhang YM (2009) Spectroscopy and Spectral Analysis 29(8), 2017-2020.
Date: 2011-08-16   Author: SKLFS  ,   Source: WOS  ,
 

Zhang QX, Wang JJ, Liu BH, Cai TL, Qiao LF, Zhang YM (2009) Gas Pipeline Leak Detection Based on Tunable Diode Laser Absorption Spectroscopy. Spectroscopy and Spectral Analysis 29(8), 2017-2020. [In Chinese]

Web link: http://dx.doi.org/10.3964/j.issn.1000-0593(2009)08-2017-04

Keywords:

Tunable diode laser, Multi-reflection cell, Wavelength modulation, Methane, Leak detection, methane, sensor

Abstract: The principle of tunable diode laser absorption spectroscopy and harmonic detection technique was introduced. An experimental device was developed by point sampling through small multi-reflection gas cell. A specific line near 1 653.7 nm was targeted for methane measurement using a distributed feedback diode laser as tunable light source. The linearity between the intensity of second harmonic signal and the concentration of methane was determined. The background content of methane in air was measured. The results show that gas sensors using tunable diode lasers provide a high sensitivity and high selectivity method for city gas pipeline leak detection.

 