Xu Q, Griffin GJ, Burch I, Jiang Y, Preston C, Bicknel AD, Bradbury GP, White N (2008a) Predicting the time to flashover for GRP panels based on cone calorimeter test results. Journal of Thermal Analysis and Calorimetry 91(3), 759-762. [In English]
Web link: http://dx.doi.org/10.1007/s10973-007-8244-z
Keywords:
cone calorimeter, flashover, GRP, ISO 9705 room, butadiene-acrylonitrile rubbers, flammability
Abstract: Cone calorimeter tests were conducted to investigate the flammability of glass-reinforced plastics (GRP) panels. The results gained from these bench scale tests were used to predict the time to flashover in the ISO 9705 room, which was partly covered by GRP panels. Ostman and Tsantaridis' empirical linear regression model and multiple discriminant function analysis (MDA) were used in the prediction. Three room-scale GRP fire tests were conducted in ISO 9705 room and the results were compared with the prediction.