homepage  Research  Publications  2008
 
Xu X, Song WG, Zheng HY (2008) Physica a-Statistical Mechanics and Its Applications 387(22), 5567-5574.
Date: 2011-08-16   Author: SKLFS  ,   Source: WOS  ,
 

Xu X, Song WG, Zheng HY (2008) Discretization effect in a multi-grid egress model. Physica a-Statistical Mechanics and Its Applications 387(22), 5567-5574. [In English]

Web link: http://dx.doi.org/10.1016/j.physa.2008.05.058

Keywords:

evacuation, cellular automata, multi-grid model, grid-independent, cellular-automaton model, pedestrian dynamics, occupant evacuation, jamming transition, simulation, flow, exit, visibility, behavior, channel

Abstract: In the traditional egress model based on cellular automata, building spaces are divided into discrete grids, the size of which is usually as large as that of a pedestrian. In order to explore the influences of the grid size on the evacuation results, we studied the evacuation process using a multi-grid egress model. In the multi-grid model, a finer grid is used and each pedestrian occupies n x n basic grids. It is found that if the pedestrian always moves one grid at each time step, the evacuation time increases with the decrease of the grid size, and reaches a stable, grid-independent value when the grid size is small enough. Another factor which influences the evacuation results is the length of the time step. It is found that with the increasing length of the time step, the evacuation time has a tendency to increase but endures complex changes. The differences between the single-grid model and multi-grid model may be due to two main reasons. First, in the multi-grid model, the pedestrians are out of alignment so that there are patches of unusable empty spaces as they are smaller in size than a pedestrian. Second, in the multi-grid model, pedestrians tend to reach the exit at the same time, leading to more serious conflicts among pedestrians. (C) 2008 Elsevier B.V. All rights reserved.

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 