homepage  Research  Publications  2010
 
Hu LH, Tang F, Yang D, Liu S, Huo R (2010) International Journal of Heat and Mass Transfer 53(13-14), 2844-2855.
Date: 2011-08-15   Author: SKLFS  ,   Source: WOS  ,
 
Hu LH, Tang F, Yang D, Liu S, Huo R (2010) Longitudinal distributions of CO concentration and difference with temperature field in a tunnel fire smoke flow. International Journal of Heat and Mass Transfer 53(13-14), 2844-2855. [In English]

Web link: http://dx.doi.org/10.1016/j.ijheatmasstransfer.2010.02.013

Keywords:

Tunnel fire, Smoke temperature, Carbon monoxide concentration, Longitudinal profile, Longitudinal ventilation, dynamics simulator comparisons, road tunnel, enclosure, corridor, velocity, spread

Abstract: Longitudinal decay profiles of CO concentration and smoke temperature in a tunnel fire smoke flow are theoretical analyzed and compared, with their difference investigated, under different longitudinal ventilation velocities. Experimental data on longitudinal CO distribution achieved from a set of full scale road tunnel fire tests are presented to compare with the theoretical equation. CFD simulations are also carried out by Fire Dynamics Simulator (FDS). It is found that the longitudinal profile of CO concentration along the tunnel yields a function of C(x)/C(0) = 1/(1 + bx), and its difference with that of the smoke temperature increases along the tunnel by a function of C(x)/C(0) - Delta T(x)/Delta T(0) approximate to lambda(1 - e(-Kx)). The smoke temperature decays much faster than the CO concentration along the tunnel. Their longitudinal profile difference decreases as the longitudinal ventilation velocity increases, and increases along with the distance away from the fire asymptotically to a quasi-steady value. The value of b decreases as the longitudinal ventilation velocity increases, which indicates that the CO concentration decays relatively slower along the tunnel under a higher longitudinal ventilation velocity. And its value is shown to be less affected by the longitudinal ventilation velocity for a relative larger fire. The increase in the longitudinal ventilation velocity leads to the enhancement of the air mass entrainment, thus results in the decrease of the longitudinal decay profile difference between the CO concentration and the smoke temperature. The value of lambda is found to decrease with the increase of the longitudinal ventilation velocity, following a reciprocal function of lambda similar to 1/(phi + alpha u). Its value at zero longitudinal ventilation velocity is higher for a larger fire, but decreases faster with the increase of the longitudinal ventilation velocity than a smaller fire. The full scale experimental data and the CFD simulation results both agree well with the theoretical analysis and equations. (C) 2010 Elsevier Ltd. All rights reserved.

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176