J. Ji, Y. B. Bi, K. Venkatasubbaiah and K. Y. Li (2016) Influence of aspect ratio of tunnel on smoke temperature distribution under ceiling in near field of fire source. Journal/Applied Thermal Engineering 106 1094-1102. [In English]
Web link: http://dx.doi.org/10.1016/j.appithermaleng.2016.06.086
Keywords: ,Tunnel fire, Tunnel width, Mass loss rate, Smoke temperature, Pool fire, HEAT RELEASE RATE, LONGITUDINAL VENTILATION, GAS TEMPERATURES, BURNING, RATE, VELOCITY, FLOW

Abstract: Former studies usually used model tunnels with fixed width while in reality the tunnel width can be different between different tunnels. In the current study, a set of small scale experiments were conducted using a model tunnel with adjustable width. The influences of tunnel width on mass loss rate, maximum smoke temperature and temperature distributions under the ceiling were investigated. Results show that under the current experimental conditions, the tunnel width has little influence on the mass loss rate and maximum smoke temperature under the ceiling. However, tunnel width significantly affects the smoke temperature distribution. The smoke temperature under the ceiling, decays more slowly at both longitudinal and transverse directions as tunnel width decreases. Empirical models are developed for both longitudinal and transverse temperature distributions which take into account the effects of tunnel width and dimensionless heat release rate. The models include exponential type functions. The index of the exponential function is proportional to the dimensionless heat release rate to the power of n. The value of n is 0.4 for longitudinal distribution and 0.5 for transverse distribution. (C) 2016 Elsevier Ltd. All rights reserved.

 
Print    Close
 
 
   
  
 
采集测试
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176