homepage  Research  Publications  2013
 
L. F. Chen, L. H. Hu, W. Tang and L. Yi (2013) Fire Safety Journal 59 94-101.
Date: 2015-06-26   Author: SKLFS  ,   Source: WOS  ,
 

L. F. Chen, L. H. Hu, W. Tang and L. Yi (2013) Studies on buoyancy driven two-directional smoke flow layering length with combination of point extraction and longitudinal ventilation in tunnel fires. Journal/Fire Safety Journal 59 94-101. [In English]
Web link: http://dx.doi.org/10.1016/j.firesaf.2013.04.003
Keywords: Tunnel fire, Point extraction, Longitudinal ventilation, Smoke flow, layering length, Model tunnel experiments, FDS, ROAD TUNNEL, TEMPERATURE, VELOCITY, SYSTEMS, CHANNEL, TESTS, FIELD
Abstract: This paper investigates the buoyancy-driven smoke flow layering length (both upstream and downstream) beneath the ceiling with combination of point extraction and longitudinal ventilation in tunnel fires. A theoretical model is developed based on previous back-laying model with only longitudinal ventilation, with modified actual heat release rate, as well as modified upstream and downstream opposing longitudinal air flow velocities by the induced flow velocity due to point extraction. Experiments are carried out in a reduced scale model tunnel with dimensionless of 72 m x 1.5 m x 1.3 m. A LPG porous gas burner is used as fire source. The smoke flow layering length both upstream and downstream are identified based on temperature profiles measured along the ceiling, for different experiment conditions. CFD simulations with FDS are also performed for the same scenarios. Results show that with combination of point extraction and longitudinal ventilation, the smoke flow layering length is not symmetric where it is longer downstream than that upstream. The upstream smoke layering length decreases, while the downstream layering length increases with increase in longitudinal ventilation velocity, and they both decrease with increase in point extraction velocity. The predictions by the proposed theoretical model agree well with the measurements and simulation results. (c) 2013 Elsevier Ltd. All rights reserved.

 
Print    Close
 
 
   
  
 
Relevant link
Contact us
State Key Laboratory of Fire Science, University of Science and Technology of China
Jinzhai Road 96, Hefei, Anhui, P. R. China
P. O.: 230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
 
 
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
Tel:(+86)551 3601651 | Fax:(+86)551 3601669 | E-mail:sklfs@ustc.edu.cn | ICP: D20380176